ABSTRACT:
Background: Over the past few years, great efforts have been made to screen duct-dependent congenital heart diseases in the newborn. Arterial pulse oximetry screening (foot and/or right hand) has been put forth as the most useful strategy to prevent circulatory collapse. The left hand, however, has always been ignored, as it was unclear if the ductus arteriosus influences left-hand arterial perfusion. A neonate undergoes major physiologic changes during transition from intrauterine to extrauterine period. The percentage saturation of hemoglobin takes about 10 minutes to reach a level of more than 90%. This fact is to be borne in mind while resuscitating a new-born with oxygen to avoid its toxicity. It is still unclear whether the oxygen saturation profile could be affected byracial/ethnic variation, birth weight, sex, APGAR score or maternal factors (age, hemoglobin, type of labour) in term healthy babies. This study aimed: 1) To note the time taken for SpO2 to reach a value of 90%, 2) To note the time taken for preductal and post ductalSpO2 to equalize and 3) To look for the association between SpO2and various infant and maternal factors. Material and Methods: A cross sectional observational descriptive study was undertaken at Pravara rural hospital, Loni (Bk). A total of 60 new-born were selected with the help of non-probability purposive sampling technique to assess the impact of selected maternal parameters on neonatal oxygen saturation levels after birth through pre and post ductal saturation monitoring at Pravara Rural Hospital, Loni (Bk). The investigator used structured questionnaire and observation checklist to collect the data. The data was analyzed with descriptive and inferential statistics wherever required. Result: The result of the study revealed that for 05 minute the reliability is 0.58 this indicates the correlation between pre and post ductal saturation with APGAR is moderately correlated. For 01 minute the reliability is 0.29 this indicates the correlation between pre and post ductal saturation with APGAR is not correlated. For 10 minute the reliability is 0.15 this indicates the correlation between pre and post ductal saturation with APGAR is not correlated. Conclusion: The major conclusion drawn from this study is that, at 01 minute SPO2 monitoring of neonates 43% had normal SPO2, 42% had decreased SPO2 (<60%) and 15% had increased SPO2 (>65%). At 05 minute of SPO2 monitoring of neonates 58% had normal SPO2, 32% had decreased SPO2(<80%) and remaining 10% had increased SPO2(>85%). At 10 minute of SPO2 monitoring of neonates 43% had normal SPO2, 40% had decreased SPO2 (<85%) and remaining 10% had increased SPO2 (>95%)
Cite this article:
Sajid Babu Shaikh, T Sivabalan. Assess the Impact of selected Maternal Parameters on Neonatal Oxygen Saturation Levels after Birth through Pre and Post Ductal Saturation monitoring at Pravara Rural Hospital, Loni (Bk). Int. J. of Advances in Nur. Management. 2021; 9(2):138-144. doi: 10.5958/2454-2652.2021.00033.0
Cite(Electronic):
Sajid Babu Shaikh, T Sivabalan. Assess the Impact of selected Maternal Parameters on Neonatal Oxygen Saturation Levels after Birth through Pre and Post Ductal Saturation monitoring at Pravara Rural Hospital, Loni (Bk). Int. J. of Advances in Nur. Management. 2021; 9(2):138-144. doi: 10.5958/2454-2652.2021.00033.0 Available on: https://ijanm.com/AbstractView.aspx?PID=2021-9-2-5
REFERENCES:
1. Baldwin HS, Dees E. Embryology and physiology of cardiovascular system. In: Avery’s Diseases of the New-born 9th ed. Philadelphia: Elsevier Saunders; 2012: 699-713.
2. Kattwinkel J, Perlman JM, Aziz K, Colby C, Fairchild K, Gallagher J, Hazinski MF, et al. Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2010;122(18 Suppl3): S909-919.
3. Perlman JM, Risser R. Cardiopulmonary resuscitation in the delivery room. Associated clinical events. ArchPediatr Adolesc Med. 1995;149(1):20-25.
4. Kurinczuk, J. J., White-Koning, M., & Badawi, N. (2010). Epidemiology of neonatal encephalopathy and hypoxic–ischaemic encephalopathy. Early human development, 86(6), 329-338.
5. Zanelli, S. A., Stanley, D. P., & Kaufman, D. A. (n.d.). What is the global prevalence of hypoxic-ischemic encephalopathy (HIE)? Retrieved March 28, 2019, from https://www.medscape.com/answers/973501-106461/what-is-the-global-prevalence-of-hypoxic-ischemic-encephalopathy-hie
6. Hypoxic-Ischemic Encephalopathy, (2019, February 03). Retrieved March 28, 2019, from https://emedicine.medscape.com/article/973501-overview#a2
7. Harigopal S, Satish HP, Taktak AFG, et al. Oxygen saturation profile in healthy preterm infants. Arch Dis Child Fetal Neonatal Ed. 2011;96: F339–42. 5 Richard D, Poets CF, Neale S, et al. Arterial oxygen saturation in preterm neonates without respiratory failure. J Pediatr. 1993;123: 963–8.
8. Ng A, Subhedar N, Primhak RA, et al. Arterial oxygen saturation profiles in healthy preterm infants. Arch Dis Child Fetal Neonatal Ed. 1998;79: F64–6.
9. Morgan MC, Maina B, Waiyego M, Mutinda C, Aluvaala J, Maina M, et al. Oxygen saturation ranges for healthy newborns within 24 hours at 1800 m. Arch Dis Child Fetal Neonatal Ed 2017;102: F266-8.
10. Saugstad OD, Aune D. In search of the optimal oxygen saturation for extremely low birth weight infants: A systematic review and meta-analysis. Neonatology 2011;100: 1-8
11. Harikrishna et al. Reference values for pulse oximetry recordings in healthy term neonates during their first 5 days of life. Arch Dis Child Fetal Neonatal Ed 2011;96: F335-8
12. Fouzas S, Priftis KN, Anthracopoulos MB. Pulse oximetry in pediatric practice. Pediatrics 2011;128: 740-52.
13. Rabi Y, Yee W, Chen SY, Singhal N. Oxygen saturation trends immediately after birth. J Pediatr 2006;148: 590-4
14. Røsvik A, Øymar K, Kvaløy JT, Berget M. Oxygen saturation in healthy newborns; influence of birth weight and mode of delivery. J Perinat Med 2009;37: 403-6
15. Ramji, S., Rasaily, R., Mishra, P., Narang, A., Jayam, S., Kapoor, A. et al, Resuscitation of asphyxiated newborns with room air or 100% oxygen at birth: a multicentric clinical trial. Indian Pediatr. 2003;40: 510–517
16. Saugstad, O.D., Rootwelt, T., Aalen, O. Resuscitation of asphyxiated newborn infants with room air or oxygen: an international controlled trial: The Resair 2 study. Pediatrics. 1998; 102: e1
17. Vento, M., Asensi, M., Sastre, J., Lloret, A., Garcia-Sala, F., Vina, J. Oxidative stress in asphyxiated term infants resuscitated with 100% oxygen. J Pediatr. 2003;142: 240–246
18. Baldwin HS, Dees E. Embryology and Physiology of Cardiovascular System. In: Avery’s Diseases of the Newborn 9th ed. Philadelphia: Elsevier Saunders; 2012:699713. 2.
19. Kattwinkel J, Perlman JM, Aziz K, Colby C, Fairchild K, Gallagher J, Hazinski MF, et al. Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2010;122(18 Suppl3): S909-919
20. Perlman JM, Risser R. Cardiopulmonary resuscitation in the delivery room. Associated clinical events. Arch PediatrAdolesc Med. 1995;149(1):20-25.
21. Bancalari E, Claure NOxygen saturation in healthy newborns; influence of birth weight and mode of delivery. Pub Med 2013;37: 404-6
22. Habib HS. Oxygen saturation trends in the first hour of life in healthy full-term neonates born at moderate altitude. Pak J Med Sci2013;29(4):903-906. doi: http://dx.doi.org/10.12669/pjms.294.3848
23. Sucheta Tiwari, Soumya Tiwari, Sushma Nangiaa, Arvind Saili, Oxygen Saturation Profile in Healthy Term Neonates in theImmediate Post Natal PeriodInt J Clin Pediatr • 2013;2(1):19-23
24. Mariani G, Dik PB, Ezquer A, Aguirre A, Esteban ML, Perez C, Fernandez Jonusas S, Fustiñana C.et alPre-ductal and post-ductal O2 saturation in healthy term neonates after birth. J Pediatr. 2007; 150(4):418-21 (ISSN: 1097-6833)
25. Melissa C Morgan, Beth Maina, Mary Waiyego, Catherine Mutinda, Jalemba Aluvaala, Michuki Maina, J Paediatr Child Health. 2018 Mar; 54(3): 260–266. Published online 2017 Oct 27. doi: 10.1111/jpc.13742.
26. Khriesat WM, Amarin ZO, Kassab M, Shkour M, AL-Maghyreh M. Oxygen saturation immediately after birth in healthy full-term neonates born below sea level. J Clin Neonatol 2016;5: 259-61